S.L. 33.1 · Manufacture And Storage Of Explosives (S.L. 33.1)
S.L. 33.1 Art. 7Directions to be observed.
The following directions shall be observed in the construction and maintenance of buildings which may be used for the manipulation and manufacture of explosives:
(a) the buildings should be low and narrow and based on sound rock foundations and sufficiently strong to withstand air pressure which may be generated by explosions in adjacent buildings;
(b) windows shall be made to fit tightly and open outwards, and are to be protected on the inside by a wire grille;
(c) door and window fastenings, hinges, bolts, locks and keys shall be made of copper or copper alloy;
(d) ventilators shall be well baffled to prevent the ingress of sparks;
(e) windows, ventilators, doors and passages shall be so arranged as to leave a current of air through the whole building when being ventilated;
(f) all inside corners in store-rooms must be rounded so as to facilitate cleaning. Floors and walls shall be kept free from cracks and crevices up to a height of one point two metres;
(g) no packages containing more than 200 lbs. of explosive material shall be stored in any building;
(h) all windows shall be of frosted wired glass;
(i) paint containing lead pigments, ground quartz or silica shall not be used;
(j) doors, windows and other wooden fittings shall be covered with sheet asbestos, sheet copper or other fire resisting material.